(9) Now screw the Connector
Locker in tight to fix the
bushing and cable.
(1) First make sure that the maximum open circuit voltage Voc of each
PV string is below 750VDC UNDER ANY CONDITION.
(2) Always connect PV-Panel positive (+) terminal to PV-Inverter DC
positive (+) terminal, and the PV-Panel negative (-) terminal to PV-
Inverter DC negative (-) terminal.
(3) Each set of PV-Inverter DC terminals takes a maximum DC input
of 8.5 A. As a result, 3 pairs of PV-Inverter DC terminals can take a
combined input of up to 25.5 A.