PV Powered 3000 Instrukcja Instalacji Strona 32

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 31
Electrical Connection SMA Solar Technology AG
32 SB25_30-IA-IEN115050 Installation Manual
5.4.3 Opening the DC Connector
1. Unscrew the cable gland.
2. To release the plug, slot a screwdriver into the side
catch mechanism and lever out. For this purpose,
use a screwdriver with a blade width of 3.5 mm.
3. Carefully pull the DC connector apart.
4. Loosen the clamping bracket. For this purpose, use
a screwdriver with a blade width of 3.5 mm.
5. Remove the cable.
The cable is removed from the DC connector.
Przeglądanie stron 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 75 76

Komentarze do niniejszej Instrukcji

Brak uwag